Buy UG-3-A40-VR06 from Calectro in Chile

BRAND Calectro
Product UG-3-A40-VR06
Description Channel smoke switch
Internal code ONR4476297
Custom code 85311030
Technical specification Calectro air duct smoke switch 24 V AC/DC The Uniguard smoke detector was developed and combined to detect smoke in ventilation ducts a smoke detector with an adapter system, whereby the pipe and housing are specially designed for optimal airflow were designed by the smoke detector. The Uniguard smoke detector has an integrated Alarm relay for controlling ventilation flaps, stopping fans and activating acoustic and visual alarms, etc. The integrated service alarm relay informs you about upcoming Maintenance work before false alarms occur. The smoke detector has an intelligent control and monitoring circuit. This circuit adjusts the sensitivity to achieve the optimal enable the smoke detector to function over its entire service life. When the the monitoring circuit can no longer compensate for contamination, a service alarm is triggered is spent. Uniguard Superflow has four pre-assembled cable entries with IP67 approval with automatic pull load anchoring for cable diameters of 4-11 mm, type Klikseal. The bayonet mount of the smoke detector makes it easy to install and remove. TECHNICAL DATA Power supply: 24 V AC/DC ± 10% Max. power consumption: 165 mA Operating temperature: -10 °C to +50 °C Maximum humidity: 99% RH Channel ventilation performance range: approx. 0.2 to 20 m/s approvals UG-3-A4O: VdS (Germany) detector head: EN-54-7 Relay output: potential-free Smoke alarm relay: Two changeover contacts 250 V, 5 A Service alarm: One changeover contact 250 V, 5 A Degree of protection: IP54

         Discover the superior quality and performance of the Calectro UG-3-A40-VR06 with Onrion LLC in Chile . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.

The UG-3-A40-VR06 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.

Key Features of UG-3-A40-VR06 :

  • High Performance: Engineered to deliver exceptional results.
  • Durable Construction: Built with high-quality materials for long-lasting use.
  • Innovative Design: Incorporates the latest technology for enhanced efficiency.
  • Cost-Effective: Offers great value for money with competitive pricing.

At Onrion LLC , we offer the UG-3-A40-VR06 at competitive prices and with the fastest delivery times across Chile . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.

Why Choose Onrion LLC ?

  • Expert Assistance: Get help from our knowledgeable team for all your product-related questions.
  • Competitive Prices: We offer some of the best prices in the market.
  • Fast Delivery: Benefit from our efficient delivery network for quick turnaround times.
  • Customer Satisfaction: Our commitment to customer service ensures a great buying experience.

Get Your Quote Today! Ready to enhance your operations with the UG-3-A40-VR06 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.     

Important Notice: While we supply Calectro products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners. 

More products of Calectro

CPS-24V - obsolete, replaced by - CPS-A

Differential air pressure transmitter

ST-P-DA

Calectro Optischer Rauchmelder-Einsatz

ST-P-DA-24VRL

Calectro Optical smoke switch 16-30 V DC, including short-circuit relay for use in raumen to fruezeitigen detections of Schwellbraenden fire and fire with smoke development .The sensor operates on the principle of scattered light, alarm relay with a potential-free changeover, including mounting base, the light transmitter and receiver are arranged in the Messa chamber so that the Lichtbuendel of the transmitter do not apply directly to the receiver kann.Erst the scattered light on suspended particles (Tyndall effect) reaches the receiver and is in an electrical signal umgesetzt.Eine green LED pollution (service), a red LED indicates the alarm. relay contact loads with 24 V / 1 A. Ambient temperature: minus 20 plus 50 degrees .Leistungsaufnahme: 2.64 watts; VDS test certificate: 205041

UG-3-A4-0

smoke detector

UG-3-O

Air duct smoke detector 24V DC

ST-P-DA-24VR

Optical Smoke Detector Insert

UG-5-AFR-230V-Z-ST2

Calectro Luftkanalrauchschalter

UG-5-AFR-230V

Duct Smoke Detector for Air Ventilation

UG-5-AFR-230V-Z

air duct smoke switch

STB-4SE-24VR

Socket for smoke detector ST-P-DA/EVC-PY-DA

UG-2-A20

Fire alarm switch

UG-5-AFR-24V-ST2

air duct smoke switch 24 V AC/DC

ST2

Venturi-Rohr Länge 600 mm für UG-5

UG-MB-75

console

UG-Cover-75

protective housing

ABAV-S3-230V

Steuergerät

CPS-A

Differential pressure transmitter -50 - +3500 Pa

Contact us for request