BRAND | Bieler Lang |
Product | CO-1000 0-300ppm |
Description | exmonitor |
Internal code | ONR5068918 |
Technical specification | Exmonitor CO-1000 Report II 2G Ex ia IIC T4 GB, BVS 03 ATEX E 384 Measurement principle: electrochemical. cell Sample gas: carbon monoxide Measurement range:0 - 1000 ppm Measurement signal: 4 - 20 mA Protection class: P 54 Weight: 1200 g Power supply: 21-28V DC SELV/PELV 2-wire technology, one-man calibration Direct access to control elements Display of the current concentration Sensor sensitivity display |
Discover the superior quality and performance of the Bieler Lang CO-1000 0-300ppm with Onrion LLC in Chile . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The CO-1000 0-300ppm is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of CO-1000 0-300ppm :
At Onrion LLC , we offer the CO-1000 0-300ppm at competitive prices and with the fastest delivery times across Chile . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Onrion LLC ?
Get Your Quote Today! Ready to enhance your operations with the CO-1000 0-300ppm ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Bieler Lang products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Where can I buy CO-1000 0-300ppm by Bieler Lang in Chile?
You can purchase CO-1000 0-300ppm by Bieler Lang from Onrion LLC. We serve customers across Chile, offering competitive prices and reliable service.
What is the price of the CO-1000 0-300ppm?
For customized pricing and availability, please fill out our contact form or give us a call. We are dedicated to providing solutions that align with your specific requirements.
Who is the official distributor or seller of Bieler Lang in Chile?
While we are not the official distributor or seller of Bieler Lang in Chile, we source our products from reliable channels and offer you original Bieler Lang equipment at competitive prices.
How can I access CO-1000 0-300ppm catalogs, user manuals, technical documents, and PDFs?
You can access catalogs, user manuals, and technical documents for CO-1000 0-300ppm on our website. Visit our resources section or contact us directly for specific documents.
Do you provide technical support for CO-1000 0-300ppm?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
sensor for 86 647
II 2 G Eex ib IIC T4,PTB 01 ATEX 2102, BAM 03 ATEX 003 Xmeasured by the sensor display of the currentConcentration of the gasesAdjustment / calibration / configuration of the sensorStoring the adjustment information forFurther processing in computer systemsAlphanumeric display, keypad for easyOperation, power supply through integratedBatteries, monitoring and display of thebattery capacityIP 54Weight: 660gDimensions HxWxD: 180x86x36mm
Gas monitor
Erstjustierung im Herstellerwerk auf 4 x Butan, 2 x Methan
Initial adjustment in the factory x 4 butane, 2 x methane
Gas Detector
gas measurement computer
gas measuring computer
gas sensor
ExDetector IR HC 33M (12.600721.3)
Gas sensor
(EC-type examination certificate BVS 03 ATEX G 007 X, PFG-No. 41300503P SIL-1 capable microprocessor technology Fault monitoring for wire breakage, power failure Short circuit and computer defect Cyclical, digital display of the current Concentration of each measuring point Alarm test without test gas Reset the horn and alarm 2 Alarm thresholds: 2 Connectable probe: 2 Design: wall mounting or standard mounting box LEDs for: Alarm 1 and 2, malfunction, sensor 1+ 2 Horn, operating Relay output for: Alarm 1 and 2 for both sensors Horn and fault Alarm 1 non-latching Alarm 2: optionally storing Supply voltage: 230V AC or 24V DC)
GASMEßFUHLER-TYP: EXDETECTOR HC 150
for use in hazardous areas of Zone 2 Housing / Electronics: II 3G Ex nA IIC T4 de Measuring head: II 2G EEx d IIC T4 PTB 00 ATEX 1076U SIL-1 capable Principle: Catalytic Measuring gas. Expl gases and vapors Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature: -20 to + 55 ° C Supply: 18V DC IP 54 Housing: Housing Aluminum, stainless steel sensor
Gasmeßfühler-Typ: ExDetector HC-100 Butan
II 2G Ex de (ib) IIC T6 PTB 00 ATEX 1075 Measuring head: II 2G Ex de IIC T4 PTB 00 ATEX 1076U EC type examination certificate: BAM 03 ATEX 0003X SIL-1 capable Principle: Catalytic Measuring gas: Butane Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature range: -20 to + 55 ° C Supply: 24V DC IP 54 Design: Sensor stainless steel, aluminum housing
Gasmeßfühler-Typ: ExDetector HC-100 methan (C4H10)
II 2G Ex de (ib) IIC T6 PTB 00 ATEX 1075 Measuring head: II 2G Ex de IIC T4 PTB 00 ATEX 1076U EC type examination certificate: BAM 03 ATEX 0003X SIL-1 capable Principle: Catalytic Measuring gas: methane Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature range: -20 to + 55 ° C Supply: 24V DC IP 54 Design: Sensor stainless steel, aluminum housing
sensor
Gas Warning Center
Gas measuring computer
sensor for the measurement of alcohol
Sensor type: Exmonitor H2-1000 Opinion II 2G Ex ia IIC t4 BVS 03 ATEX E 384 Principle: elektrochem. cell Measuring gas: Hydrogen Measuring range: 0 - 1000 ppm Measuring signal: 4 - 20 mA IP 54 Weight: 1200g Supply: 21-28V DC 2-wire, man calibration, Display current concentration Direct access to the controls, Display of the sensitivity of the sensor, When used in hazardous areas, the Use of barriers necessary
(Gas sensor type: ExDetector HC-100K, Ex certificates enclosure / electronics: II 2G Ex de (ib) IIC T6 PTB 00 ATEX 1075 Measuring head: II 2G Ex de IIC T4 PTB 00 ATEX 1076U EC type examination certificate: BAM 03 ATEX 0003X SIL-1 capable For installation in ventilation ducts Principle: Catalytic Measuring gas: u Expl gases.. fumes Range: 0 - 100% LEL Measuring signal: 4 - 20 mA Temperature range Housing: -20 to + 55 ° C Sensor temperature range: -20 to + 80 ° C Supply: 24V DC IP 54 Design: Sensor stainless steel, aluminum housing)
gas sensor ExDetector HC 150