H2 1000   - Bieler Lang Chile  Sales

BRAND Bieler Lang
Product H2 1000
Description Sensor type: Exmonitor H2-1000 Opinion II 2G Ex ia IIC t4 BVS 03 ATEX E 384 Principle: elektrochem. cell Measuring gas: Hydrogen Measuring range: 0 - 1000 ppm Measuring signal: 4 - 20 mA IP 54 Weight: 1200g Supply: 21-28V DC 2-wire, man calibration, Display current concentration Direct access to the controls, Display of the sensitivity of the sensor, When used in hazardous areas, the Use of barriers necessary
Internal code ONR296209
Weight 1

Please Contact Us to Order to offer competitive prices and delivery time for Bieler Lang - H2 1000 Sensor type: Exmonitor H2-1000 Opinion II 2G Ex ia IIC t4 BVS 03 ATEX E 384 Principle: elektrochem. cell Measuring gas: Hydrogen Measuring range: 0 - 1000 ppm Measuring signal: 4 - 20 mA IP 54 Weight: 1200g Supply: 21-28V DC 2-wire, man calibration, Display current concentration Direct access to the controls, Display of the sensitivity of the sensor, When used in hazardous areas, the Use of barriers necessary number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Chile Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Bieler Lang

HC 100 K ( 12.100920.3)

Front probe with sensor

HC 200

Gas sensor

Typ 8022

Gas Measurement Computer

Typ: Gasmonitor O2

Meßfühler-Typ: Gasmonitor O2

12.600534.5, Type: 8022

Gas measuring computer

Gasmesscomputer Typ : 8022

(EC-type examination certificate BVS 03 ATEX G 007 X, PFG-No. 41300503P SIL-1 capable microprocessor technology Fault monitoring for wire breakage, power failure Short circuit and computer defect Cyclical, digital display of the current Concentration of each measuring point Alarm test without test gas Reset the horn and alarm 2 Alarm thresholds: 2 Connectable probe: 2 Design: wall mounting or standard mounting box LEDs for: Alarm 1 and 2, malfunction, sensor 1+ 2 Horn, operating Relay output for: Alarm 1 and 2 for both sensors Horn and fault Alarm 1 non-latching Alarm 2: optionally storing Supply voltage: 230V AC or 24V DC)

SC-220M

Gas measurement sensor Type: ExDetector

Calibration CH-4 of the ExDetector HC 100-M in workshop on metan

Initial adjustment to explosive gases in the manufacturer's plant

QS-3950-1

Gas Detection

HC100-D1

Measuring head front part with sensor

8022E

gas measuring computer

Ecoline HC50

Gas sensor type: Ecoline HC50

12.101075.2 ( for type ExDetector HC-150)

Measuring head front part with sensor

Other Category Brands

Contact us for request