BRAND | Labom |
Product | CV3100-A1053-F10-H1100-M1-N10-T20-K1110 |
Description | Pressure transmitter pascal |
Internal code | ONR4668112 |
Custom code | 90262020 |
Technical specification | CV310 PRESSURE TRANSMITTER PASCAL CV with threaded connection acc. to data sheet D4-017-1 A1 pressure sensor: piezoresistive for gauge pressure 053 nominal range: 0...1 bar, overload limit 3 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F10 measuring range: 0...1.000 bar H11 output signal: 4...20 mA, rising characteristic (standard) 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) M1 display module: without screw cap closed, without window N10 switching module: without case: hygienic housing design with screw cap material: stainless steel degree of protection: IP 66 T10 electrical connection: cable gland M 16 x 1.5, polyamide black K1110 process connection: diaphragm flush-mounted, G 1/2 B with O-ring from EPDM material: - diaphragm, stainless steel mat. no. 1.4404/1.4435 (316L) - socket, stainless steel mat. no. 1.4404/1.4435 (316L) # Spare part for 1504763/06/013 |
Discover the superior quality and performance of the Labom CV3100-A1053-F10-H1100-M1-N10-T20-K1110 with Onrion LLC in Chile . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The CV3100-A1053-F10-H1100-M1-N10-T20-K1110 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of CV3100-A1053-F10-H1100-M1-N10-T20-K1110 :
At Onrion LLC , we offer the CV3100-A1053-F10-H1100-M1-N10-T20-K1110 at competitive prices and with the fastest delivery times across Chile . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Onrion LLC ?
Get Your Quote Today! Ready to enhance your operations with the CV3100-A1053-F10-H1100-M1-N10-T20-K1110 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Labom products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
GA2700-HY-A1011-C1025-G11-N3-T150
[RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology Sheet according T4-015 RTD: 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 11 nominal diameter: 1/2 B conical sealing C1 Temperature sensor: ø 6 mm 025 Installation length U1: 25 mm G11 Material wetted parts: stainless steel mat 1.4404 (316L) N3 measuring insert: 1 x Pt 100 (bridged 3-wire) in 4-wire technology T150 electrical connection: Circular connector M 12x1 (4 poles) Range of -50 ... + 200 ° C]
GA2700-HY-A1031-C4025-G11-N2-T150-Z52 PA2430-F12-H1
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm tapered for a diameter of 4 mm 025 installation length U1: 25 mm G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100 in 3-wire, standard T150 electrical connection: circular connector M 12x1 (4 poles ) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430) PA243 transmitter for temperature (Pt 100), programmed according to data sheet T4-082-1 electrical connection. round connector M12x1 (4-pole) 0 type: standard configuration F12: see below measuring range: 0 ... + 150 ° C leakage current with sensor break: 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
GA2700-HY-A1031-C4030-G11-N2-T150-Z52 PA2430-F12-H1
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm, tapered to ø 4 mm 030 installation length U1: 30 mm G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100 in 3-wire, standard T150 electrical connection: circular connector M 12x1 (4 poles) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430. ) PA243 TRANSMITTER (for temperature Pt 100), programmed according to data sheet T4-082-1 electrical connection: circular connector M12x1 (4-pole) 0 Type: standard configuration F12: see below measurement range: 0 ... + 150 ° C leakage current with sensor break : 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
GA2700-HY-A1031-C4990-G11-N2-T150-Z52 PA2430-F12-H1
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm tapered for a diameter of 4 mm 990 Einaulänge U1 (in mm): 20 G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100-3-wire system, standard T150 electrical connection: circular connector M 12x1 (4 poles) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430) PA243 transmitter for temperature (Pt 100), programmed according to data sheet T4-082-1 electrical connection. round connector M12x1 (4-pole) 0 type: standard configuration F12 : see below measurement range: 0 ... + 150 ° C leakage current with sensor break: 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
GA2720-A99-C4025-G11-N2-T150-Z52-W4035-W4020-W5422-W1020 PA2430-F12-H1
(RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology with separate thermowell Explosion protection: without welded thermowell according to drawing B4-CA-00019-z (PG-MB-00025-k))
Measuring range 0 ... 250 ° C
MANOMETER 0 ÷ 25 MPA; Ø100; M20H1 5: ACCURACY CLASS 1.6
1. Scope - 0 ÷ 250 kgf / cm 2. Accuracy class - 1.6 3. Diameter - Ø 100 4. Join-radially by thread M20x1.5
MANOMETER 0 ÷ 40 MPA; Ø 100; M20XL, 5; ¬ CLASS 1.6 ACCURACY.
1. Scope -0 ÷ 400 kgs/sm2 2. Accuracy class - 1.6 3. Diameter-Ø 100 4. Join radial-threaded M20h1 5
MULTIFUNCTION DISPLAY for PASCAL CV
MiniTherm GA 2700 ½” gear (-50…+200°C)
Resistance Thermometer
(MT8 weld G 1/2 100 conically sealing, material stainless steel mat 1.4404 A1 without inspection hole)
CV3110-A1051-F10-H1100-M1-N10-T4-T20-K1085-K80
PRESSURE TRANSMITTER
pascal cv supply 24 v dc
material inspection certificate
PRESSURE GAUGE NG 63 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH51 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A58 display range: 0 ... 10 bar Overload protection: 1.3 times Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 10 Enclosure: IP 65 Process connection back HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 20 Enclosure: IP 65 with case filling, process connection bottom HY surface roughness: according to the hygienic design A90 display range: -1 ... 5 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 Enclosure: IP 65 with case filling, process connection on the back 30 HY surface roughness: according to the hygienic design A57 display range: 0 ... 6 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
PRESSURE GAUGE NG 100 ECO for food / pharmaceutical / biotechnology Sheet according D2-028-5 BH52 Enclosure: IP 65 with case filling, process connection on the back 30 HY surface roughness: according to the hygienic design A91 display range: -1 ... 9 bar Overload protection: 1.3 times Hands: with micro Case Filling: glycerol-water Process connection: Tri-Clamp, DN 1 1/2 " Material stainless steel mat 1.4404 / 1.4435 (316L) System filling: Food oil FD1, gem. FDA approval class USDA H1 Operating temperature range 0 ... + 140 ° C
CI4120-A1061-F2-H21-Y12-T200-K1086 DL2100-A3007-L22
DRUCKMESSUMFORMER PASCAL Ci4 für Druckmittler