BRAND | Badger Meter |
Product | 1004GCN36HVXE60PST |
Description | 1" control valve |
Internal code | ONR4048222 |
Technical specification | Typ RC 200 1" RCV TYPE 200 Body :Globe casted, 316SST Connection :1" NPT internal threads Bonnet :Heavy Duty guided, 316SST Packing :PFA/TFE CV-ring Innervalve :Size "6.0" =%, Cvs=6,0, HD-guiding Inn.material :Plug stellite / Seat stellited 316SST Actuator :Electric actuator Type HH-500 SBA06-4, 2kN 230 VAC, 3 Point Control, Protection Class IP65 2 additional Limitswitches Stainless Steel coupling,-coloumns |
Discover the superior quality and performance of the Badger Meter 1004GCN36HVXE60PST with Onrion LLC in Chile . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The 1004GCN36HVXE60PST is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of 1004GCN36HVXE60PST :
At Onrion LLC , we offer the 1004GCN36HVXE60PST at competitive prices and with the fastest delivery times across Chile . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Onrion LLC ?
Get Your Quote Today! Ready to enhance your operations with the 1004GCN36HVXE60PST ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Badger Meter products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Where can I buy 1004GCN36HVXE60PST by Badger Meter in Chile?
You can purchase 1004GCN36HVXE60PST by Badger Meter from Onrion LLC. We serve customers across Chile, offering competitive prices and reliable service.
What is the price of the 1004GCN36HVXE60PST?
For customized pricing and availability, please fill out our contact form or give us a call. We are dedicated to providing solutions that align with your specific requirements.
Who is the official distributor or seller of Badger Meter in Chile?
While we are not the official distributor or seller of Badger Meter in Chile, we source our products from reliable channels and offer you original Badger Meter equipment at competitive prices.
How can I access 1004GCN36HVXE60PST catalogs, user manuals, technical documents, and PDFs?
You can access catalogs, user manuals, and technical documents for 1004GCN36HVXE60PST on our website. Visit our resources section or contact us directly for specific documents.
Do you provide technical support for 1004GCN36HVXE60PST?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
RCDL LCR REGISTER MIT IMPULSAUSGANG U. STROMAUSGANG 4-20MA
Electronic counter LCR type with an LCD display, Display 1: resettable totalizer or Flow display programmable, Format xxx.xx. Display 2: Non-resettable totalizer 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA
RCDL LCR REGISTER OHNE IMPULSAUSGANG
Electronic counter LCR type with an LCD display, for the OG series Display 1: resettable totalizer or Flow display programmable, format xxxx.x Display 2: Non-resettable totalizer 14 digits Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64
3/4 "or 1" PPO Viton without pulse, fluid meter RCDL M25 without construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, standing
Vectra Viton pulse PFT-2 reed contact Liquid meter RCDL M25 without construction. Materials and technical data: Housing: Bronze Measuring chamber: Vectra O-rings: Viton Measuring range: 3-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: ° C Connection: R 1 "outside Installation length: 190 mm Installation position: horizontal, standing 604011 Pulse PFT-2 reed contact about 52 PPL
liquid meter
RCDL M25 3/4" ODER 1" PPO VITON OHNE IMPULSGEBER
(Liquid meter RCDL M25 without Construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, vertical)
RCDL M25, WITH PULSE- TRANSMITTER PFT-1E - 52,4 PULSE/LITER SETUP
Housing : Bronze Chamber : Noryl (PPO) O-Rings : Buna Flowrange : 1-100 l/min Accuracy : +/- 1,5 % of value p-max : 10 bar t-max : 50 °C Connection : Threads 1" male Laylength : 190mm Pulsoutput : Open Collector NPN Scale Factor : 0.00001 to 0.9999 Supply : 12-24 VDC Pulsoutput : S/N : Part-Nr. 141158
MID M 2000 mit Flansch DN 50 1.4571
Oval wheel counter
PN : MID M 1000, Type : Typ ModMAG M1000
magnetic inductive flowmeter
Electromagnetic Flow Meter
Pulse Flow meter
P/N: 9008527 Type: MID M 1000 DN 50/16
Magnetisch-Induktiver-Durchflußmesser
Magnetisch-Induktiver-Durchflußmesser
102460 LM OG-PNDA electronic preset counter
Elektronischer Vorwahlzähler
MN 2 ASP – 1 obsolete/replaced by IOG BSP 1/4" ALU 1.4571
flowmeter for diesel
Impulsgeber
Signal Transmitters
MID2-25/16- F/St-HG- MEL/HC-St
flowmeter
magnetic flow meter
Electronic Circuit Board
Flüssigkeitsmengenzähler